info@lehrs.be

+32 475 832 875

Dennenlaan 1,

B-2222, Heist-op-den-Berg, Belgium

Burners

Technical Data Burner G7

Technical Data
Burner G7

Fuel

Natural gas

 

Propane / Butane

Burner Capacity

50 – 200 kWatt

Mode of control

On / Off

Safety device

Safety & Control Box

Flame monitoring

Ionisation

Nominal motor capacity :

165 Watt

Nominal voltage

220 V – 50 / 60 Hz

Gas supply :

3/4 “

 

Natural gas : 25 – 70 mB

 

Propane / Butane : 35 – 50 mB

Gas valve :

220 V – 50 / 60 Hz   – 36 Watt

 

Max pressure : 500 mB

Operation heat values :

Natural Gas Low : Hu = 8.83 kWh / Nm³

 

Natural Gas High : Hu= 10.35 kWh / Nm³

 

Butane : Hu = 34.29 kWh / Nm³

 

Propane : Hu = 25.9 kWh / Nm³

Dimensions :

Width : 325 mm

 

Height : 675 mm

 

Depth : 350 mm

Weight net :

22 Kg

Weight gross :

23 Kg

 

 

TECHNICAL DATA SAFETY & CONTROL BOX

Nominal Voltage :

110 / 220 V – 50 / 60 Hz

Ignition time :

Variable 1 – 30 sec

Shut – off time :

Variable 1 – 30 sec

Run signal :

Contact closed – or – In 24/110/220V

Generated alarms :

Contact closed – or – Out 24/110/220V

Indications :

Burner heating : green

 

Burner in alarm : red

Dimensions :

H 400 x W 300 x D 220 mm – weight 9 Kg

SPECIAL DEMANDS : Our burners can be adapted to all your special demands.

hover to enlarge

Mu nv / G-Lehrs

MU nv / G-Lehrs is a Belgian company founded in 1993 and is exclusively active in the world of glass.